EN

Translate:

Fuel Storage Systems

01226 753160 - info@fuelstoragesystems.com

  • Home
  • Industries
    • Commercial
    • Generators
    • Retail
    • Marine
    • Engine Test Cell
    • Rail
    • Fire Pump
    • Workshop Oils
    • Heating Oil
  • Products
    • Pumps
    • Pipework
    • Tanks
    • Chambers
    • Leak Detection
    • Fill Cabinets
    • Gauges
    • Fuel Polishing
    • Fuel Management
    • Alarms
    • Filters
    • Fuel Meters
    • Duplex Pumps
    • EV Charging
  • Services
    • Installation
    • Maintenance
    • Electrical
    • Construction
    • Environmental
    • Fuel Conditioning
    • Tank Lining
    • Testing
    • Testing - NDT
    • Bund Sealing
    • OFTEC
    • Vapour Recovery
    • Bio Diesel
    • AdBlue
  • Regulations
  • Blog
  • Careers
  • Contact Us
  • More
    • Home
    • Industries
      • Commercial
      • Generators
      • Retail
      • Marine
      • Engine Test Cell
      • Rail
      • Fire Pump
      • Workshop Oils
      • Heating Oil
    • Products
      • Pumps
      • Pipework
      • Tanks
      • Chambers
      • Leak Detection
      • Fill Cabinets
      • Gauges
      • Fuel Polishing
      • Fuel Management
      • Alarms
      • Filters
      • Fuel Meters
      • Duplex Pumps
      • EV Charging
    • Services
      • Installation
      • Maintenance
      • Electrical
      • Construction
      • Environmental
      • Fuel Conditioning
      • Tank Lining
      • Testing
      • Testing - NDT
      • Bund Sealing
      • OFTEC
      • Vapour Recovery
      • Bio Diesel
      • AdBlue
    • Regulations
    • Blog
    • Careers
    • Contact Us
Fuel Storage Systems

01226 753160 - info@fuelstoragesystems.com

EN

  • Home
  • Industries
    • Commercial
    • Generators
    • Retail
    • Marine
    • Engine Test Cell
    • Rail
    • Fire Pump
    • Workshop Oils
    • Heating Oil
  • Products
    • Pumps
    • Pipework
    • Tanks
    • Chambers
    • Leak Detection
    • Fill Cabinets
    • Gauges
    • Fuel Polishing
    • Fuel Management
    • Alarms
    • Filters
    • Fuel Meters
    • Duplex Pumps
    • EV Charging
  • Services
    • Installation
    • Maintenance
    • Electrical
    • Construction
    • Environmental
    • Fuel Conditioning
    • Tank Lining
    • Testing
    • Testing - NDT
    • Bund Sealing
    • OFTEC
    • Vapour Recovery
    • Bio Diesel
    • AdBlue
  • Regulations
  • Blog
  • Careers
  • Contact Us

Environmental Protection

Leak Detection Services

 Here at Fuel Storage Systems, the protection of the environment is one of the main objectives. With high standards and application specific product solutions including fuel storage tank alarms, we contribute to the active protection of our environment. We believe that you can never be too safe when working with fuels, this is why we offer a wide array of environmental safety systems. It is through these systems that you will often discover that prevention really is better than the cure.


 This is where leak detection systems come in, no organisation or system is ever going to be one hundred percent safe from failing or leaking, so a leak detection system is the perfect way to spot a problem before it impacts your business. Continuous and reliable monitoring with clearly indicated alarm signals lowers the risk of not recognising leaks on tanks and pipework to an absolute minimum with all our systems comply with the environment agency standards .  



Equipment Range

Fuel Tank Alarm Unit

LAD-10 Fuel Tank Leak Detection System

LAD-R Pipework Leak Detection System

Tank Alarm Kit


  • 3 x channels with options for High Level, Low Level and Bund Alarms.
  • ATEX Certified. 
  • Suitable with Diesel, Bio Diesel, Kerosene, Oil & Adblue.
  • Weather proof to IP55.
  • 98dB sounder & flashing beacon.
  • Options for output relay - volt free contact for each channel.
  • Power supply 230V or battery operated. 

Find out more

LAD-R Pipework Leak Detection System

LAD-10 Fuel Tank Leak Detection System

LAD-R Pipework Leak Detection System

LAD-R Pipework Leak Detection System

  •  Suitable for Diesel, Gas Oil & Adblue.
  • Approved for use with double walled pipes steel or plastic.
  • Optical and audial alarm. 
  • Output relay - volt free contact.
  • Power Supply 240V. 
  • Class-I-system in accordance to the European standard EN 13 160.  

LAD-10 Fuel Tank Leak Detection System

LAD-10 Fuel Tank Leak Detection System

LAD-10 Fuel Tank Leak Detection System

LAD-10 Storage Tank Leak Detection System

  • Suitable for Petrol, Diesel, Gas Oil & Adblue.
  • Approved for use with double walled pipes steel or plastic.
  • Optical and audial alarm. 
  • Output relay - volt free contact.
  • Power Supply 240V. 
  • Class-I-system in accordance to the European standard EN 13 160.  

TraceTek Leak Detection Cable

LDU 14 ATEX Tank & Pipework Leak Detection System

LAD-10 Fuel Tank Leak Detection System

TraceTek Leak Detection Cable


  • Detects the presence of hydrocarbon fuels.
  • Water resistant.
  • Up to 100 M of cable.
  • Suitable for Petrol, Diesel, Gas Oil & Adblue.
  • Pinpoints the location of the leak.
  • 90dB sounder
  • Weather proof to IP55.
  • Output relay - volt free contact
  • Power supply 230V or 12Vdc


LDU 14 ATEX Tank & Pipework Leak Detection System

LDU 14 ATEX Tank & Pipework Leak Detection System

LDU 14 ATEX Tank & Pipework Leak Detection System

LDU 14 ATEX Tank & Pipework Leak Detection System

  • Suitable for Petrol, Diesel, Gas Oil & Adblue.
  • Approved for use with double walled pipes & tanks steel or plastic.
  • Monitors up to 12 tanks & 12 lines.
  • Optical and audial alarm.
  • Lines charged with oxygen free nitrogen.
  • Weather proof to IP55.
  • Dry Filter.
  • Output relay - volt free contact.
  • Power Supply 240V 
  • Class-I-system in accordance to the European standard EN 13 160.  

Find out more

OSA Oil Separator Alarm

LDU 14 ATEX Tank & Pipework Leak Detection System

LDU 14 ATEX Tank & Pipework Leak Detection System

OSA Oil Separator Alarm


  • Monitors the level of the separated liquid in Oil/Petrol separators. 
  • Suitable for Petrol & Diesel.
  • Weather proof to IP65.
  • Power supply 230V.
  • Out put relay.
  • Audible and visual alarm.
  • ATEX approved.

Automatic Oil/Water Discriminating Bund Pump

Automatic Oil/Water Discriminating Bund Pump

Automatic Oil/Water Discriminating Bund Pump

Automatic Bund Pump

Control Panel

  • Power: 110/230 V AC, 440 Watts
  • Construction: Stainless steel, IP66 rated
  • Dimensions: 320 mm (H) x 260 mm (H) x 120 mm (D)
  • LED Indicators; Mains Supply, Pump Active, High Water Alarm, High Oil Alarm, Pump Disable
  • Outputs: Mains fail, High Water, High Oil, Pump Disable 
  • Fixing: Wall/surface mount via external mounting lugs

Sensor Unit

  • Power & Voltage: nominal 
  • Construction: Stainless steel, immersion proof
  • Dimensions: 570 mm (H) x 180 mm (W) x 70 mm (D)
  • Fixing: Free standing in base of sump

Pump

  • Power: 230 VAC (110V AC optional)
  • Construction: Stainless steel
  • Dimensions: 250 mm (H) x 160 mm (W)
  • Flow Rate: 110 litres per minute at 2-3 metre head

Hydrocarbon Discriminating Sensor

Automatic Oil/Water Discriminating Bund Pump

Automatic Oil/Water Discriminating Bund Pump

Hydrocarbon Discriminating Sensor


  • Magnetic float switches detect liquid at two levels.
  • Innovative polymer strip indicates hydrocarbons along sensor and floating on water.
  • Compatible with fuels and chemicals.
  • Detects liquid at a height of 38 mm.
  • Detects hydrocarbons on sensor and floating on water.
  • Digitally encoded status information sent from microcomputer to console.
  • Alarms to indicate liquid in sump, hydrocarbons detected and sensor malfunction.

TS-LS 300 Electronic Line Leak Detection

Automatic Oil/Water Discriminating Bund Pump

TS-LS 300 Electronic Line Leak Detection

Electronic Line Leak Detection

  • Automatically maps exact pipe system characteristics.
  • No pipe type or length programming required.
  • Monitors flexible, plastic and steel  pipework in any combination up to certified maximum values.
  • Automatically performs 3.0 gph, 0.2 gph and 0.1 gph line tests.
  • Positive submersible turbine pump shutdown on the activation of a leak alarm.
  • Can be monitored through ATG and System Sentinel™.
  • Third party certified for 0% probability of false alarm.
  • Immediate notification of alarm Situations.
  • Allows printed compliance reports.

The APEA Awards 2021

Head Office: 20-22 Hawley Street, Block 2, Pennine Five, Sheffield, S1 2EA


Operations Office: Unit 8, Silverwood Court, Fairfield Park, Manvers, Rotherham, South Yorkshire, S63 5DB




Powered by